A circuit protection device that opens (breaks) the circuit on excess current and can be reset and reused, unlike a fuse. A trip-free breaker opens even if its handle is held in the ON position; a nontrip-free breaker can be held on during an overcurrent.

How it works

A circuit breaker stops current in a circuit on a direct short, excess current or excess heat, and unlike a fuse it is reset, not replaced. The Navy text lists five components: frame, operating mechanism, arc extinguishers and contacts, terminal connectors and trip elements. The operating handle shows when the breaker has tripped by sitting between ON and OFF.

The trip element decides how it behaves. A thermal element uses a bimetallic strip heated by load current, so it reacts to a small overload that goes on for a long time and trips faster on a larger one. A magnetic element uses an electromagnet in series with the load and trips at once when the preset current is reached. A thermal-magnetic breaker combines the two, covering sustained overload and sudden surge.

Trip-free and nontrip-free breakers differ. A trip-free breaker opens even if the handle is held ON. A nontrip-free breaker can be held on during an overload, which suits essential circuits such as emergency lighting. Engine room breakers must be calibrated for a 50 degree C ambient temperature under 46 CFR 111.54-1, unless in a controlled machinery control room, where 40 degrees C is the standard.

What to know for the exam

  • QMED Electrician and Designated Duty Engineer questions ask what a thermal-type breaker senses, which kind of breaker serves essential circuits such as emergency lighting, what a breaker and a fuse have in common, what a handle resting between ON and OFF after an overload indicates, and why breakers in series have different time delays.
  • Maintenance questions come from NEETS Module 3: get approval, remove power, tag the switch, then inspect. If the contacts show pitting from arcing, smooth them with a fine file or number 00 sandpaper.
  • Regulation questions pull in 46 CFR Part 111: the ambient temperature calibration for breakers in engine rooms, how the breakers on switchboards are arranged, and the longtime trip setting for a ship's service generator breaker.

Common questions

Sources

  • NEETS Module 3, Circuit Protection, Control and Measurement, Chapter 2, Circuit Protection Devices, and Appendix INEETS Module 3
  • NEETS Module 3, Circuit Protection, Control and Measurement, Chapter 2, Circuit Breakers (trip elements; trip-free)NEETS Module 3
  • 46 CFR Part 111 (Electric Systems), 111.54-1 (circuit breakers)46 CFR 111.54-1 on eCFR