Exam reference: GS-0011 (the label exam questions use for this figure)

FIGURE · VERTICAL LUBE OIL PUMP DIMENSIONS AND DATATAP TO ENLARGE

What the figure shows

A side view of a vertical pump with the electric motor on top, a central housing with the outlet flange, and a long suction casing ending in an inlet at the bottom. Dimension lines give each height in feet and inches. Two tables list the motor data (25 HP, 1200 RPM, 440 volts, 60 cycles, 3 phase) and the pump data (400 GPM, 1150 RPM, 55 PSIG discharge).

How to read it

  1. Locate the centerline of the discharge outlet on the housing, then the dimension lines that run up from it.
  2. Add or subtract the stacked heights to get a distance no single arrow shows, keeping feet and inches straight.
  3. Use the tables, not the drawing, for ratings such as speed, capacity, voltage and discharge pressure.

What exam questions ask

  • The distance from the center of the discharge outlet to the top of the motor. Combine the dimension lines between those two points; the result is 36 inches.

Related figures