Skip to content
Mariner IQ
Start Free
Steam & Boilers

Saturated Steam Table: Condenser Vacuum and Temperature

Exam reference: SG-0026 (the label exam questions use for this figure)

FIGURE · CONDENSER VACUUM VS. STEAM TEMPERATURE TABLETAP TO ENLARGE

What the figure shows

A table titled Properties of Saturated Steam with three columns: vacuum in inches of mercury gauge, temperature in degrees C and temperature in degrees F. Rows run from 29.51 inches (53.14 F) down to 1.42 inches (209.56 F), so each vacuum reading has its matching temperature.

How to read it

  1. Find the vacuum reading in the first column, then read across to the Fahrenheit column for the saturation temperature.
  2. Higher vacuum means lower saturation temperature; the table runs from deep vacuum at the top to near atmospheric at the bottom.

What exam questions ask

  • Given a condenser vacuum and a hot well temperature, how much condensate depression is there? Find the saturation temperature for that vacuum and subtract the hot well temperature; the result is a small difference of a few degrees.

Common mistakes

  • Reporting a large number: condensate depression is a small temperature difference, not a value near the condensate temperature itself.

Related figures

All exam figuresPractice on the QMED Fireman / Watertender practice test